PE Butt Fusion Drainage Fittings Clean Out With Steel
Clean Out With Steel
Main Functions
Internal Pipe Inspection and Observation
By opening the stainless steel blind plate cover (quickly removed via bolts or clips), the interior of the vertical stack can be directly inspected using an endoscope, camera, or the naked eye:
Presence of blockages or accumulation of foreign objects (hair, grease, construction debris, etc.);
Water flow conditions, air-water mixture, and negative pressure formation;
Scaling, corrosion, or deformation on the pipe wall;
Whether the siphonic effect is functioning normally (full-bore negative pressure flow, no air entrainment).
Pipe Descaling and Unblocking
When the system becomes blocked, cleaning tools (such as drain snakes, pipe inspection robots, or high-pressure water jets) can be inserted directly through the opening for clearing, without the need to disassemble large sections of piping or damage walls/floors. This is especially suitable for the same-floor drainage principle of "maintenance on the same floor without disturbing other levels."
System Maintenance and Fault Diagnosis
Routine inspection of the siphonic system’s air venting performance, negative pressure stability, and air expulsion;
Checking for leaks at heat-fusion/electrofusion joints (micro-leaks are more easily amplified under negative pressure);
Verifying the airtightness of the piping (critical for siphon activation);
Convenient for collecting water samples or testing water quality (particularly useful in rainwater harvesting or reclaimed water systems).
Emergency Drainage and Pressure Relief
In extreme situations (such as system overload, abnormal negative pressure, or sudden blockages), the blind plate can be temporarily removed to serve as a pressure relief point or auxiliary drainage outlet, preventing pipe bursting, siphon interruption, or system collapse.
Main Roles (Unique Value)
Enhanced Negative Pressure Sealing and Durability: The 304 stainless steel blind plate offers superior corrosion resistance, anti-aging, UV resistance,
Internal Pipe Inspection and Observation
By opening the stainless steel blind plate cover (quickly removed via bolts or clips), the interior of the vertical stack can be directly inspected using an endoscope, camera, or the naked eye:
Presence of blockages or accumulation of foreign objects (hair, grease, construction debris, etc.);
Water flow conditions, air-water mixture, and negative pressure formation;
Scaling, corrosion, or deformation on the pipe wall;
Whether the siphonic effect is functioning normally (full-bore negative pressure flow, no air entrainment).
Pipe Descaling and Unblocking
When the system becomes blocked, cleaning tools (such as drain snakes, pipe inspection robots, or high-pressure water jets) can be inserted directly through the opening for clearing, without the need to disassemble large sections of piping or damage walls/floors. This is especially suitable for the same-floor drainage principle of "maintenance on the same floor without disturbing other levels."
System Maintenance and Fault Diagnosis
Routine inspection of the siphonic system’s air venting performance, negative pressure stability, and air expulsion;
Checking for leaks at heat-fusion/electrofusion joints (micro-leaks are more easily amplified under negative pressure);
Verifying the airtightness of the piping (critical for siphon activation);
Convenient for collecting water samples or testing water quality (particularly useful in rainwater harvesting or reclaimed water systems).
Emergency Drainage and Pressure Relief
In extreme situations (such as system overload, abnormal negative pressure, or sudden blockages), the blind plate can be temporarily removed to serve as a pressure relief point or auxiliary drainage outlet, preventing pipe bursting, siphon interruption, or system collapse.
Main Roles (Unique Value)
Enhanced Negative Pressure Sealing and Durability: The 304 stainless steel blind plate offers superior corrosion resistance, anti-aging, UV resistance,
Quantity
| Specification |
| JF-MBTL75 |
| JF-MBTL90 |
| JF-MBTL110 |
| JF-MBTL125 |
| JF-MBTL160 |
| JF-MBTL200 |
| JF-MBTL250 |
| JF-MBTL315 |